Air-water heat pumps
WPL 25 ACS – Technical Data
-
Type
Product Number
236643
Output at A2/W35 (EN 14511)
8,33 kW
Output at A-7/W35 (EN 14511)
12,86 kW
Coefficient of performance at A2/W35 (EN 14511)
4,14
Coefficient of performance at A-7/W35 (EN 14511)
2,98
Technical data
Energy efficiency class, heat pump W35
A+++
Energy efficiency class, W55 heat pump
A++
Energy efficiency class, composite system (heat pump + controller) W35
A+++
Energy efficiency class, composite system (heat pump + controller) W55
A++
SCOP (EN 14825)
4,53
Cooling capacity at A35/W7 max.
14,88 kW
Cooling capacity factor at A35/W7 max.
2,38
Cooling capacity at A35/W7 partial load
6,76 kW
Cooling capacity factor at A35/W7 partial load
2,93
Sound power level (EN 12102)
54 dB(A)
Sound pressure level at 5 m distance in a free field
32 dB(A)
Rated compressor voltage
230 V
Rated voltage, emergency/booster heater
230 V
Max. application limit on the heating side
65 °C
Height
1045 mm
Width
1490 mm
Depth
593 mm
Weight
175 kg